Expectant mothers at work: have the EMF answer ready

An expectant mother is one of the workers the law singles out for special consideration. The EMF thresholds that protect her are several times lower than those for the general workforce, and the most sensitive weeks are often before anyone at work has been told. This short video and the guide below explain what the law requires, where to look, and how to have the answer ready.

What the law requires

Two sets of duties apply. The Management of Health and Safety at Work Regulations 1999 (regulation 16) require the risk assessment to cover risks to new and expectant mothers, and non-ionising radiation is one of the physical agents to consider. The Control of Electromagnetic Fields at Work Regulations 2016 and the HSE’s guidance single out expectant mothers as workers at particular risk.

“You must give special consideration to the safety of employees at particular risk (even if you are in compliance with the exposure limits).”
HSE HSG281, paragraph 49

Why the map must come first

The most sensitive weeks of a pregnancy are often before anyone at work has been told. So the time to find out where the higher fields are is before you need the answer.

  • Before. Map the areas above public reference levels, and tell staff the map exists.
  • Notified. Check her tasks and routes against the map, and agree any changes.
  • During. Keep the changes in place, and review them if her work changes.
  • Return. Restore normal duties and record the review.

Much lower thresholds

The unborn child is not an employee, so her exposure is usually kept within the public reference levels in Council Recommendation 1999/519/EC. These are between 5 and 50 times lower than the values for the general workforce.

FieldPublic levelWorkforce valueHow much lower
Static magnetic field40 mT2,000 mT (ELV)50×
50 Hz magnetic field100 µT1,000 µT (Low Action Level)10×
RF heating (whole body)0.08 W/kg0.4 W/kg (SAR ELV)5×
RF power density, 10–400 MHz2 W/m²10 W/m² (Action Level)5×

Where to look

Most areas of most sites are well below the public levels, and office equipment, phones and Wi-Fi are not a concern. The zones that matter are close to particular industrial sources:

  • Induction heaters and furnaces
  • Radio transmitters and antennas
  • RF plastic welders and sealers
  • MRI and NMR magnets
  • Switchboards and transformers
  • Resistance and arc welding
  • Large motors and drives
  • Microwave heating and drying

With a site map in place, each notification is a desk review, not a new survey.

A simple decision path

  • Does her work take her into areas above public reference levels? If not, no change is needed. Record it and tell her.
  • If it does, can the task or route change so she stays below them? If so, adjust her duties or access for the pregnancy.
  • If not, offer suitable alternative work. Suspension on full pay is the legal backstop.

Suitable alternative work, and suspension on full pay where none is available, are rights under the Employment Rights Act 1996.

Common misunderstandings

  • “We’ll deal with it when someone tells us.” The most sensitive weeks are often before anyone has been told. Map the site first.
  • “She should avoid all electrical equipment.” Most of most sites is well below the public levels. Only a handful of zones near particular sources matter.
  • “Phones and Wi-Fi are a worry.” Office equipment, phones and Wi-Fi are well below the public reference levels.
  • “Every notification needs a new survey.” With a site map in place, it is a desk review.

In short

Map once. Then every notification gets a quick, confident answer, and nobody is moved off work they could safely do.

The same lower thresholds matter for workers with implanted devices: see Pacemakers at work: the people the EMF limits don’t cover. For how all these numbers fit together, see Action Levels, ELVs and reference levels.

Pacemakers at work: the people the EMF limits don’t cover

The EMF exposure limits at work are set for the general workforce. They do not protect people with pacemakers, defibrillators or other implanted and body-worn medical devices. Those workers need much lower thresholds, and the places where those thresholds are exceeded are usually close to ordinary equipment, not exotic sources. This short video and the guide below explain who is at risk, how much lower the thresholds are, and what to do about it.

Who is at particular risk

The HSE’s guide to the Control of Electromagnetic Fields at Work Regulations 2016, HSG281, names these workers specifically.

“You must make sure you take employees at particular risk, such as expectant mothers and workers with active or passive implanted or body-worn medical devices, into account …”
HSE HSG281, paragraph 12 (extract)

There are three groups, each with a different risk:

  • Active implants. Pacemakers, defibrillators, neurostimulators and cochlear implants. Interference can make the device pause, deliver a shock or reset.
  • Body-worn devices. Insulin pumps, glucose monitors and other worn electronics. Interference can affect readings or drug delivery.
  • Passive implants. Joint replacements, plates, pins and stents. These can heat up in strong RF and induction fields, and feel forces near strong magnets.

Much lower thresholds

Implanted devices are designed to work normally in fields up to the reference levels for the general public in Council Recommendation 1999/519/EC. EN 50527-1, the standard for assessing workers with implants, uses those levels as its starting point. For static fields, a specific threshold of 0.5 mT applies. Interference is instantaneous, so readings are compared without time averaging.

FieldImplant thresholdWorkforce valueHow much lower
Static magnetic field0.5 mT2,000 mT (ELV)4,000×
50 Hz magnetic field100 µT1,000 µT (Low Action Level)10×
50 Hz electric field5 kV/m10 kV/m (Low Action Level)2×
Radiofrequency, 100 MHz28 V/m61 V/m (Action Level)2×

Distance is the main control

Fields around most workplace equipment fall away quickly with distance. Near a typical source, the 50 Hz magnetic field can drop below the 100 µT implant threshold within about a metre. So the usual answer is a clearly marked zone rather than new equipment or shielding.

A signed boundary also protects the people you don’t know about: visitors, contractors, and staff who have not told you about a device.

A practical approach

Five steps cover most sites:

  • Identify. Invite confidential disclosure through occupational health.
  • Map. Survey where fields exceed implant thresholds.
  • Mark. Put in zones, signs and inductions for staff, visitors and contractors.
  • Check. Carry out an individual assessment with device data where needed.
  • Review. Look again when there is a new device, new equipment or a change of layout.

Common misunderstandings

  • “Modern pacemakers are shielded.” They are designed to cope with fields up to public reference levels, not with workplace fields that can be many times higher.
  • “We’d know if anyone had one.” Workers do not have to tell you. Invite confidential disclosure, and sign zones so everyone is covered.
  • “A quick walk past is fine.” Interference is instantaneous. Brief exposure above the threshold can still affect a device.
  • “Leave it to their cardiologist.” Cardiologists know the device, not your site. They need your field data to advise.

In our experience

Almost every site has areas above implant thresholds, usually close to everyday equipment: switchboards, cables, motors, welders and induction heaters. Most can be managed with a marked zone and a short briefing.

For how implant thresholds compare with the other numbers in an EMF report, see Action Levels, ELVs and reference levels: what the numbers mean.

Action Levels, ELVs and reference levels: what the numbers in an EMF report mean

EMF reports quote Action Levels, exposure limit values and reference levels, often on the same page. They are not interchangeable. Confusing them can lead a report to declare a site compliant while missing the people most at risk, or to raise alarm over a reading that is not a breach at all. This short video and the guide below explain what each number means, who it protects, and how a good report should set them out.

Outside the body, and inside it

The legal limits in the Control of Electromagnetic Fields at Work Regulations 2016 are the exposure limit values (ELVs). They apply to what happens inside the body: the electric field induced in tissue at low frequencies, and heating, measured as the specific absorption rate (SAR), at radio frequencies. These cannot be measured in a person, so they are calculated with computer models of the human body.

So the Regulations also set Action Levels. These are field strengths in the workplace that can be measured with an instrument. They are set so that if they are met, the ELVs are met too.

  • Action Levels (outside the body). Electric field (V/m), magnetic flux density (µT) and, at radio frequencies, power density (W/m²). Measured with an instrument.
  • Exposure limit values (inside the body). Induced electric field (V/m) and specific absorption rate (W/kg). Calculated with body models.

What a reading tells you:

  • Below the Action Level. The ELV is met. No further work is needed for the general workforce.
  • Above the Action Level. Not yet a breach. Calculate the ELV before drawing any conclusion.

Who each number protects

The Action Levels are set for the general workforce. They do not protect people with pacemakers or other active implants, or expectant mothers, who must be given special consideration under the HSE’s guide to the Regulations, HSG281.

“You must give special consideration to the safety of employees at particular risk (even if you are in compliance with the exposure limits).”
HSE HSG281, paragraph 49

For these workers, the lower reference levels for the general public in Council Recommendation 1999/519/EC are used. At 50 Hz, the magnetic field threshold for workers at particular risk is ten times lower than the Low Action Level.

Threshold at 50 HzApplies toMagnetic fieldElectric field
Reference levelWorkers at particular risk100 µT5 kV/m
Low Action LevelSensory effects1,000 µT10 kV/m
High Action LevelHealth effects6,000 µT20 kV/m
Limb Action LevelArms and legs only18,000 µTn/a

These are the values at 50 Hz, the frequency of mains electricity. All of them change with frequency. At 100 MHz (FM radio), for example, the electric field Action Level is 61 V/m and the reference level 28 V/m.

What a result means in practice

A measured value only means something when it is compared with the right threshold. The same reading can be unremarkable for most staff and a real concern for one person. A good report shows the measured value, each threshold as a number, the percentage, and the outcome for each group of workers.

Location (illustrative 50 Hz results)Measured% of Low AL (1,000 µT)% of reference level (100 µT)Outcome
Office, first floor0.3 µT< 1%< 1%No restriction
Cable riser40 µT4%40%No restriction
Switchboard, front face220 µT22%220%Restrict access for workers at particular risk
Transformer enclosure, 0.2 m1,400 µT140%1,400%Calculate ELVs; keep-out zone

AL = Action Level. Where a Low Action Level is exceeded, the Regulations allow it in some circumstances, provided the ELVs are shown to be met or specified conditions are applied.

Four common confusions

“Above the Action Level means we’re breaking the law.” Not necessarily. The legal limits are the ELVs. Exceeding an Action Level means more assessment, usually by calculation.

“Below the Action Levels, so it’s safe for everyone.” It is safe for the general workforce. Workers with implants and expectant mothers need the lower reference levels.

“The report says it meets ICNIRP.” Which values? ICNIRP publishes occupational and public levels, in 1998 and 2010 versions. Ask for the numbers applied.

“One measurement covers the site.” Limits depend on frequency. A 50 Hz reading says nothing about a radio transmitter or an induction heater.

What we see in practice

The reports that cause problems tend to share the same faults: limits that are not stated, a bare claim of “ICNIRP compliance” with no numbers behind it, and sites declared compliant with no thought for anyone with a pacemaker. None of that is obvious to the reader until something goes wrong.

A sound report leaves no room for doubt. Every result sits next to the threshold it was compared with, the frequency is stated, and the outcome is given separately for the general workforce and for workers at particular risk.

In short: ask any EMF report three things: which limits it applied, stated as numbers; at what frequency; and for whom.

Sources: The Control of Electromagnetic Fields at Work Regulations 2016 (SI 2016/588). Directive 2013/35/EU, Annexes II and III. HSE (2016) Electromagnetic fields at work, HSG281. Council Recommendation 1999/519/EC. ICNIRP (1998, 2010) guidelines.

Choosing an EMF assessor: twelve questions to ask before you commit

Anyone can buy a meter and call themselves an EMF specialist. There is no accreditation scheme for EMF assessors, quotes vary widely, and a cheap assessment can look complete while missing the risks that matter. The legal duty stays with the employer either way. This short video and the guide below set out the questions worth asking any assessor before you commit.

The assessor

1. Who will actually do the work, and what is their track record in EMF? A credible assessor will say who they are, what they have done and for whom, and send an example report. If a quote says nothing about the person doing the work, ask why. Newcomers may be cheaper, but usually for a reason.

2. Is their expertise actually in electromagnetic fields? A general science or safety qualification is not enough, and experience in ionising radiation does not carry across: the physics, limits and methods are completely different. Ask how many workplace EMF assessments they have carried out.

3. What credentials do they hold, and who issued them? There is no accreditation scheme for EMF assessors, so be wary of web-based or unfamiliar “EMF certificates”. The meaningful recognised status is Chartered Radiation Protection Professional (CRadP), awarded by the Society for Radiological Protection.

4. Is EMF their core business, or a sideline? Some large general health and safety firms added EMF because they saw the enquiries coming in, not because they have the expertise. Ask who in the company has done this work before, and how often.

5. Do they offer home surveys or sell protection products? Firms that sell shielding or market “EMF surveys” to worried householders have an interest in finding problems. Fields in homes are generally weak and well within safety thresholds. An independent assessor sells neither products nor fear.

The equipment and method

6. What instruments will they use, and are they calibrated? Ask for the make and model of each instrument and its calibration certificate. Consumer “EMF meters” bought online are not designed for compliance work and cannot support a legal assessment.

7. Can they measure every kind of field on your site? Different kinds of field need different instruments. Fields from drives, welders and induction heaters are not simple sine waves and need the weighted-peak method described in the HSE’s guidance, HSG281.

FieldFrequencyTypical sourcesNeeds
Static0 HzMRI and NMR magnets, industrial magnets, DC busbars, electrolysisStatic magnetometer
Low frequency1 Hz – 100 kHzCables, transformers, motors and drives, welding, induction heatingLF analyser, weighted-peak method
Radiofrequency100 kHz – 300 GHzRadio transmitters and antennas, RF heaters and sealers, radar, satellite uplinksBroadband or selective RF meter

8. Will they assess workers at particular risk? People with pacemakers and other implants, and expectant mothers, are protected by much lower thresholds than the general workforce. An assessment that checks only the Action Levels can declare a site compliant while missing exactly the places that matter.

Example: 50 Hz magnetic field near a switchboard, measured at 500 µTThresholdResult
Checked against the Low Action Level only1,000 µT“Compliant”
Checked for workers at particular risk100 µTExceeded

At 50 Hz, the reference level in Council Recommendation 1999/519/EC is used to assess workers at particular risk. The same reading can pass one check and fail the other.

9. Will they cover your whole site, not just the obvious source? The duty covers employees wherever they work: electrical rooms, plant rooms, workshops and roofs, not just the machine that prompted the enquiry. Agree the full scope before the visit.

The report

10. Will the report give the numbers, the standards and a clear verdict? You should see the limits applied, stated as numbers, the measurement standards followed, and a plain answer: compliant or not, and against what. Ask to see a sample report.

11. Will it tell you what to do, and what you don’t need to do? A good report turns measurements into practical controls, such as separation distances, signage, procedures and review triggers, and says plainly where no action is needed.

12. Is the price fixed, and what does it include? Check whether the visit, report, any modelling, RAMS and follow-up questions are included. A short visit with a few spot readings is not a site-wide assessment.

Warning signs

  • No named assessor, no CV and no example report
  • A quote given without any questions about your site
  • “EMF certification” from an online course
  • Consumer meters, or no instrument details at all
  • No mention of pacemakers, implants or expectant mothers
  • Results without the limits they were compared against
  • Selling shielding, “protection” products or home surveys
  • Alarming language with no clear, practical actions

What we see in practice

Over the years we have seen reports with no limits stated, measurements made with instruments that could not see the fields actually present, and sites declared compliant with no thought for anyone with a pacemaker. None of that is obvious to a buyer until something goes wrong. These questions are worth asking of anyone, including us.

The short version: compare quotes on who will do the work, what they will measure with, whether they will consider the people most at risk, and what the report will tell you, not on price alone.

Sources: The Control of Electromagnetic Fields at Work Regulations 2016 (SI 2016/588). HSE (2016) Electromagnetic fields at work, HSG281. Council Recommendation 1999/519/EC.

Is an EMF assessment optional? What CEMFAW Regulation 5 requires

An EMF assessment is often treated as a “nice to know”, something to get round to if budget allows. It is not. Assessing electromagnetic field exposure is a legal duty on every employer under UK health and safety law. This short video and the guide below set out what the Regulations and the Health and Safety Executive actually say.

What the law says

“The employer must make a suitable and sufficient assessment of the levels of electromagnetic fields to which employees may be exposed.”
The Control of Electromagnetic Fields at Work Regulations 2016, regulation 5(1)

“The employer must review the assessment when— (a) there is reason to suspect it is no longer valid; or (b) there has been a significant change in the matters to which it relates …”
The Control of Electromagnetic Fields at Work Regulations 2016, regulation 5(4) (abridged)

The word is must, not “should” or “may”. Failing to comply with a duty in health and safety regulations is a criminal offence under section 33 of the Health and Safety at Work etc. Act 1974.

What the HSE expects in practice

The HSE’s guide to the Regulations, HSG281, turns the duty into five practical steps. Together they describe a continuing process, not a single survey.

  1. Assess. Measure or calculate the fields wherever employees work (regulation 5(1)).
  2. Compare. Check exposure against the exposure limits (HSG281, paragraph 32).
  3. Protect. Give special care to workers at particular risk (HSG281, paragraph 49).
  4. Act. Put an action plan in place where it is needed (HSG281, paragraph 12).
  5. Review. Revisit the assessment after any significant change or new information (regulation 5(4)).

“You must give special consideration to the safety of employees at particular risk (even if you are in compliance with the exposure limits).”
HSE HSG281, paragraph 49

In short: the question is not whether to assess EMF exposure, but whether the assessment you have is suitable and sufficient. If you have no assessment, you are not complying.

Four common misunderstandings

“It’s optional: nice to know, if there’s budget.” The employer “must make a suitable and sufficient assessment”. It is a duty, not a recommendation.

“We only need to look at the obvious equipment.” The duty covers “the levels of electromagnetic fields to which employees may be exposed”, wherever they work.

“Nobody here has a pacemaker.” Exposure must be assessed for all staff. People at particular risk, such as workers with medical implants and expectant mothers, come on top of that, and you may not know who they are.

“We had it checked years ago.” The assessment must be reviewed after “a significant change”: a move, new equipment, a new layout.

A recent example

A major energy company asked us to re-survey a test laboratory after it moved to a new site. Both its safety staff and its managers regarded EMF assessment as optional. The laboratory turned out to be safe for all staff, with one simple precaution kept for people with pacemakers. But the duty does not stop at the lab door: the rest of the site, where the same employees work, had never been assessed.

Our report set out the legal position, so that the safety team could take the remaining areas to management with the evidence behind them.

In our experience, almost every site has areas where the fields exceed the levels that protect workers with medical implants and expectant mothers, usually close to everyday equipment such as switchboards, cables, motors and welders, not just the obvious sources.

Need an assessment, or a second opinion on the one you have?

EMFcomp carries out independent EMF assessments to the Control of Electromagnetic Fields at Work Regulations 2016 for employers across the UK. Email enquiries@emfcomp.com with a short description of your site and we will tell you what a suitable and sufficient assessment would involve.

Sources: The Control of Electromagnetic Fields at Work Regulations 2016 (SI 2016/588), regulation 5, www.legislation.gov.uk/uksi/2016/588. HSE (2016) Electromagnetic fields at work: A guide to the Control of Electromagnetic Fields at Work Regulations 2016, HSG281, paragraphs 12, 32 and 49, www.hse.gov.uk/pubns/books/hsg281.htm. Health and Safety at Work etc. Act 1974, section 33. Extracts are reproduced verbatim and contain public sector information licensed under the Open Government Licence v3.0.